เครื่องวัดความขุ่น HANNA HI88713

Details

The HI88713 Precision ISO Turbidity Benchtop Meter is specially designed for water quality measurements, providing reliable and accurate readings, even within low turbidity ranges. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.

 

Features at-a-glance:

Four Measurement Modes - The HI88713 features four options for turbidity measurement: FNU (Formazin Nephelometric Units), FAU (Formazin Attenuation Units), and NTU (Nephelometric Turbidity Units) ratio and non-ratio mode. Turbidity ranges for each mode are 0.00 to 1000 FNU, 10.0 to 4000 FAU, 0.00 to 4000 NTU (ratio mode), and 0.00 to 1000 NTU (non-ratio mode).

Multiple Turbidity Units of Measure - Turbidity can be read as Formazin Nephelometric Units (FNU), Formazin Attenuation Units (FAU), European Brewing Convention units (EBC), and Nephelometric Turbidity Units (NTU).

ISO Compliant - The HI88713 meets and exceeds the requirements of ISO 7027 method for turbidity measurements by use of an infrared LED light source.

Calibration - The HI88713 has a powerful calibration function that compensates for variation in light intensity. The calibration can be done using the supplied calibration solutions or user-prepared standards. A two, three, four, or five-point turbidity calibration can be performed by using the supplied (<0.10, 15, 100, 750 FNU, and 2000 NTU) standards. Calibration points can be modified if user-prepared standards are used.

AMCO AEPA-1 Primary Turbidity Standard - The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.

GLP Data - The HI88713 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time.

Data Logging - Up to 200 measurements can be stored in the internal memory and recalled at any time.

Data Transfer - For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the USB port and the HI92000 software.

Tutorial Mode -  The unique tutorial mode provides additional information to help the user during measurements. When enabled, the instrument displays explanations and a confirmation button when a preparation or other operation has to be performed.

Contextual Help - Contextual help is always available through a dedicated HELP button. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.  The help information displayed is relative to the setting/option being viewed.

Backlit Graphic LCD Display - A graphic LCD display provides an easy to understand, user-friendly interface. All messages are in plain text making them easy to read.

 


 

Turbidity Specifications

FNU Range 0.00 to 9.99 FNU, 10.0 to 99.9 FNU, 100 to 1000 FNU
FNU Resolution 0.01 FNU, 0.1 FNU, 1 FNU
FNU Accuracy ±2% of reading plus stray light
FAU Range 10.0 to 99.9 FAU, 100 to 4000 FAU
FAU Resolution 0.1 FAU, 1 FAU
FAU Accuracy ± 10% of reading
Non-Ratio Mode Range 0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 1000 NTU 0.00 to 9.99 EBC; 10.0 to 99.9 EBC; 100 to 245 EBC
Non-Ratio Mode Resolution 0.01; 0.1; 1 NTU; 0.01; 0.1; 1 EBC
Non-Ratio Mode Accuracy ±2% of reading plus stray light
Ratio Mode Range 0.00 to 9.99 NTU; 10.0 to 99.9 NTU; 100 to 4000 NTU 0.00 to 9.99 EBC; 10.0 to 99.9 EBC; 100 to 980 EBC
Ratio Mode Resolution 0.01; 0.1; 1 NTU; 0.01; 0.1; 1 EBC
Ratio Mode Accuracy ±2% of reading plus stray light, ±5% of reading above 1000 NTU
Range Selection automatic
Repeatability ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater
Stray Light < 0.02 NTU (0.15 Nephelos; 0.01 EBC)
Light Detector silicon photocell
Method nephelometric method (90°) or ratio nephelometric method (90° & 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B
Measuring Mode normal, average, continuous
Turbidity Standards < 0.1, 15, 100, 750 and 2000 NTU
Calibration two, three, four, or five-point calibration

General Specifications

Light Source IR LED
Display 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
Log Memory 200 records
Connectivity USB
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Power Supply 12 VDC adapter (included)
Dimensions 230 x 200 x 145 mm (9.0 x 7.9 x 5.7”)
Weight 2.5 kg (88 oz.)
Ordering Information HI88713 is supplied with sample cuvettes and caps (6), calibration cuvettes, silicone oil, cuvette wiping cloth, power adapter, and instruction manual.
Warranty 2 years